A drive failed in RAID 5: don't hit "rebuild" yet
LostData lab team · · 2 min read
if a drive fails in RAID 5, don't start a rebuild before the drives are copied. A second weak drive during the rebuild can take the whole array down.
How RAID 5 works
Data is spread over all the drives with parity information, so the array survives one failed drive and only one. Once the first drive fails, the array runs with no protection left, and any further read error can stop it.
Why a rebuild is risky
A rebuild reads every sector of every drive for many hours. Drives in an array are often from the same batch and the same age, so if one is weak the others are not far behind. One bad sector or a second weak drive during the rebuild can stop it halfway, and that is when recovery gets harder.
What to do now
- Stop any rebuild that hasn't started, and don't press Initialise or Create new volume.
- Shut the system down cleanly if you can.
- Write the slot number on each drive before removing it.
- Don't run CHKDSK, fsck or recovery software on the original drives.
- Write down what happened: error messages, the last update, and which drive failed first.
How we work
We never rebuild on your drives. We copy each drive separately through a write blocker, repairing a failed drive first like any hard drive. Then we work out the drive order, stripe size and parity, rebuild the array virtually from the copies, and send you the file list to check.
Cost and emergencies
An array rebuild starts from 1,500 SAR, plus each failed drive at its own fault level. If your business is down, we offer a 24-hour emergency service. Call 0543222284.